Om Cat C15 (60 Hz)

 

The C15 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 320 to 500 ekW at 60 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and built to accept 100 percent rated load in one step. The engines are certified to the US EPA Tier 4 Final emissions levels. Seismic certification is also available for select models, so you can deliver power despite disturbances. Our integrated control system, including ATS and switchgear ensure a consistent power supply and connection to your fleet through on-site and remote monitoring options. We offer a wide range of EMCP 4 control panel options, with a simple screen display, consolidating all your management and diagnostics tools. The optional EMCP 4.4 provides multi generator set paralleling capability, allowing you to use multiple generator sets for increased power output and improved reliability. It's not just quality that matters but customization, choose from a broad range of accessories and bolt-on system expansion attachments. Discover our flexible upgradeable packaging options to work with your spatial restrictions and environmental conditions. Our C15 generator sets are developed for such prerequisites, so that you can meet your specific power needs. Build in additional safety features with the UL 2200 and CSA certified package options.

Spesifikasjoner

Generator Set Specifications
Height - Maximum 82.4 in
Length - Maximum 168.2 in
Width - Maximum 81 in
Minimum Rating 320 ekW
Maximum Rating 500 ekW
Voltage 208 to 600 Volts
Frequency 60 Hz
Speed 1800 RPM
Generator Set Configurations
Emissions/Fuel Strategy Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards
Engine Specifications
Motormodel C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Compression Ratio 16.1:1
Aspiration Air to Air Aftercooled
Governor Type Adem™A4
Fuel System MEUI
Bore 5.4 in
Displacement 927.56 in³
Stroke 6.75 in

Egenskaper

Design Criteria

Design Criteria
The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response.

Cat Diesel Engine

Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
  • Generator

    Generator
  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
  • Cat EMCP Control Panel

    Cat EMCP Control Panel
    The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

    Single-Source Supplier

    Single-Source Supplier
    Fully prototype tested with certified torsional vibration analysis available

    World Wide Product Support

    World Wide Product Support
    Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

    Seismic Certification

    Seismic Certification
  • Seismic Certification available.
  • Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength.
  • IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer
  • Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007, CBC 2010
  • Pre-approved by OSHPD and carries an OSP-0321-10 for use in healthcare projects in California
  • Se produktet i 360°

    Drag your mouse to rotate the product

    Kontakt

     

    Ta kontakt hvis du har spørsmål.

     

    • Call
    • Arrow

     

    OSLO

    Bølerveien 60
    N-2020 Skedsmokorset

    Pon Power:        +47 23 17 05 00
    E-post:                [email protected]

    Send meg et tilbud. 

    250/250
    Jeg ønsker å motta nyhetsbrev fra Pon.
    Kontakt Tilbake Icon - Contact Sticky Cross
    • Call
    • Arrow

    RING OSS

    Send oss en e-post

    Vi svarer deg så fort vi kan.

    Hvordan foretrekker du at vi kontakter deg? *
    250/250

     

    ELLER FYLL UT SKJEMA HER:

     

    Fyll ut skjemaet nedenfor, så kontakter jeg deg så snart som mulig.

     

    Hvordan vil du at vi skal kontakte deg? *
    250/250
    web-monitoring-ok